Operating and Installation Instructions for the ACTpro 4000 Access Control System 18-00071
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Assign PINs The Assign PINs func
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ If the cards entered are already
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Assign Names The Assign Names f
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Option Description 2 Activate
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ System Log The System Log menu a
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ The event types that can be filt
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ the tracking area, however users
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ access. As an example: In a man
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ 6) Clearing a time zone A B C D
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Change PIN The Change PIN funct
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Contents About ACTpro 4000………………
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Installer Menu System Settings
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Exit Always Time zones don’t
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Push Button Push Button even
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Network Mask Sets the Network
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ System Settings The System Sett
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ The ACTpro 4000 display supports
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ • Tracking Reset is used to aut
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Operation This menu allows the i
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ • The Door Forced alarm occurs w
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ unlocked. The Green LED on the R
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ User Tracking……………………………………………
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Communications on the controller
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ TCP/IP Settings ACTpro 4000 sup
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ NetBIOS Name The NetBIOS name is
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ whenever additional cards or tag
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Reader Test The Reader Test Menu
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ 31 It is always a good idea to
5A 250VAC5A 30VDC1A 250VAC1A 30VDC0VDOORCONTACTPUSHBUTTONAUXINPUTRELAY 1N/C N/OCOP2OP3SENSECLOCKDATAREDGREENB 0VTXRXNETWORK 11A 250VAC1A 30VDC+DOORSAB
OP1TAMPERMAINSPRESENT+ 12V DC- NCCOP2 NONCCNOSENSE0VRED GREEN+5VCLOCKDATA5A 250VAC5A 30VDC5A 250VAC5A 30VDC1 2 3 4 5 6 7 8N ADDRESSOnOP3 OP4 0
Card / Proximity or PinReader (Entry)Card or ProximityReader (Exit)ControllerSENSECLOCKDATA+12V0VREDGREENCard/Prox ReaderFor Wiegand Exit readersConne
ACTpro 4000 TCP/IP FeaturesLINKSPEEDLEDS:LINK illuminates to indicate good Ethernet connection.It will also flicker when data is recieved from the net
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Central/Sat……………………………………………
ACTpro 4000 TCP/IP Settings1. Enter the IP address, Network Mask, Default Gateway and Port Number from Installer Menu->TCP/IP Settings.2. Connect
ACTWin pro Serial ConfigurationACTWin proFrom the Installer Menu on the keypad,do the following:1. Factory Default the controller.2. For more than one
37ACTpro 4000 USB SettingsACTpro 4000 supports USB connection from a PC.Connect the PC to the Micro USB connector at the top of the pcb. Both LEDs abo
Setup for Network Operation 4 3 2 1BAUDRATE SELECT960019200Network cable use either:(1)Single shielded twisted pair: Belden 9501 or similar(2)CAT5
39AutodiscoverACTpro 4000 supports the autodiscover function in ACTWin 2.8 and later. New ACTpro 4000 controllers on an IP network may be found by ACT
Max cable length is 5m using standard alarm cableor 30m using twin twisted-pair (use 0V in each pair)DB25 Male(Rear View)723Serial Modem Cable (Modem
SERIAL NETWORKENTRY/EXIT READEROP1TAMPERMAINS+12V0VN/C COP2N/ON/C C N/OSENSECLOCKDATA+5V0VRED GREEN5A 250VAC5A 30VDC5A 250VAC5A 30VDCIP3IP2IP10VOP4O
To PCTo Mains SupplyACT 4-Line Nework Interface CardAll lines are equivalent and operate in parallel Any controller may be connected to any line.Netwo
ACTpro 4000 Hub OperationThe ACTpro 4000 can be used as a Hub to connect up to a total 16 controllers to a PC using just one COM port or USB port, wit
A B0VTXRXNETWORK 1DOORSAB0VSERIAL0VREDGREENA B0VNETWORK 2TXRXNETWORK 1DOORSAB0VSERIAL/PRINTER0VDTRREDGREENA B0VNETWORK 2CTSNETWORKDOORSSERIAL/PRINTER
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ About ACTpro 4000 The ACTpro 400
ACTpro 4000 SDCardThe ACT SDCard enables extra features of the ACTpro 4000: 1. 4th and 5th Card for each user. Each user can have up to 5 cards.
SENSECLOCKDATA+5V0VRED GREEN+12V5A 250VAC5A 30VDC5A 250VAC5A 30VDC1 2 3 4 5 6 7 8OnNETWORKImportant !Always Place VaristorAcross Lock TerminalsBAShiel
DB25 Male(Rear View)73 2Max cable length is 5m using standard alarm cableor 30m using twin twisted-pair (use 0V in each pair)Direct Connection from Mo
DisarmedAlarm PanelOptional signal from the alarm panel to indicate armedor disarmed status. If 0V is connected to AUX Input,the panel is armed. Note
TAMPERMAINSPRESENT+ 12V DC- NCCNO1 2 3 4 5 6 7 8OnNETWORK 1BAShieldACT4000AB0VAB0VTotal Length max 1.4kmNetwork cable use either:(1)Single shiel
ACTWin proACTWin proACTpro 4000ACTpro 4000ACTpro 2000ACTpro 3000ACTpro 3000ACTpro 3000ACTpro 100ACTpro 100 ACTpro 100 ACTpro 100 ACTpro 100 ACTpro 100
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Operating Instructions The ACTpr
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Operator Menu User Setup Enabl
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Time Zones Specify the time
ACTpro 4000 Operating Instructions 1.00 __________________________________________________________________________ Also any user may be displayed b
Comments to this Manuals